No products in the cart.
Panasonic CS-RZ35AKRW – Developer Series 3.5kW High Wall (Unit)
$559.99$639.99 (-13%)
🏆 Best Price Guaranteed*
🏆 Best Price Guaranteed*
💬
Custom Quote Required
Direct checkout is temporarily disabled for this item. Please use the Request Quote / Enquiry button below to get accurate pricing and availability.
Genuine Panasonic CS-RZ35AKRW Developer Series high wall unit (3.5kW). Brand new, 5-year Panasonic warranty, NZ-wide delivery.
Discount per Quantity
| Quantity | 1 | 2 - 4 | 5 - 9 | 10 + |
|---|---|---|---|---|
| Discount | 0% | 5% | 8% | 10% |
| Price | $559.99 | $531.99 | $515.19 | $503.99 |
Panasonic CS-RZ35AKRW – Developer Series 3.5kW High Wall (Unit): Genuine Panasonic Trade Supply
You are viewing the Panasonic CS-RZ35AKRW – Developer Series 3.5kW High Wall (Unit) (SKU: CS-RZ35AKRW). This is a 100 percent genuine Panasonic Developer Series High Wall Indoor Units component, engineered for New Zealand homes and commercial sites. Refrigerant: R32. Cooling capacity: 3.5kW. Heating capacity: kW.
Product Details: Panasonic CS-RZ35AKRW
Panasonic CS-RZ35AKRW – genuine Panasonic Developer Series high wall unit, brand new with full NZ warranty support.
Key Features
- ✓ POWERFUL Mode
- ✓ ECO Mode with A.I.
- ✓ Inverter Control
- ✓ Sleep Mode
- ✓ Quiet Mode
- ✓ Fan Mode
- ✓ Soft Dry Operation Mode
- ✓ Hot Start Control
- ✓ Auto Changeover (Inverter)
- ✓ Manual Horizontal Airflow Direction Control
- ✓ Airflow Direction Control (Up & Down)
- ✓ Anti-Bacterial Filter
- ✓ Odour Removing Function
- ✓ Removable Washable Panel
- ✓ 24-Hour Dual ON & OFF Real Setting Timer
- ✓ Demand Response Enabling Device (DRED)
- ✓ LCD Wireless Remote Control
- ✓ Wired Remote Control (Optional)
- ✓ Random Auto Restart (32 Restart Patterns)
- ✓ Blue Fin Condenser
- ✓ Top Panel Maintenance Access
- ✓ Self-Diagnostic Function
Panasonic CS-RZ35AKRW — Full Specifications
| Unit Overview | |
| Cooling Capacity | 3.5 kW |
| Brand | Panasonic |
| Series | Developer Series |
| SKU | CS-RZ35AKRW |
| Warranty | 5 Years |
| Capacity & Performance | |
| Cooling Capacity (min-max) (kW) | 3.50 (1.00-4.20) kW |
| Heating Capacity (min-max) (kW) | 4.00 (0.90-5.70) kW |
| Cooling Capacity (min-max) (Btu/h) | 11,900 (3,410-14,300) Btu/h |
| Heating Capacity (min-max) (Btu/h) | 13,600 (3,070-19,400) Btu/h |
| Cooling Indoor Air Flow (L/s) | 193 L/s |
| Heating Indoor Air Flow (L/s) | 202 L/s |
| Dehumid (L/h) | 2.00 L/h |
| Cooling AEER/EER | 4.22 W/W / 4.27 W/W |
| Heating ACOP/COP | 4.55 W/W / 4.60 W/W |
| Star Rating Residential/Commercial – Cooling (Hot Climate) | 4.5/5.5 TCSPF |
| Star Rating Residential/Commercial – Cooling (Average Climate) | 4.5/6.5 TCSPF |
| Star Rating Residential/Commercial – Cooling (Cold Climate) | 4.5/8.0 TCSPF |
| Star Rating Residential/Commercial – Heating (Hot Climate) | 3.5/3.5 HSPF |
| Star Rating Residential/Commercial – Heating (Average Climate) | 3.0/3.5 HSPF |
| Star Rating Residential/Commercial – Heating (Cold Climate) | 2.5/3.0 HSPF |
| Electrical | |
| Cooling Running Current (A) | 3.60 A |
| Heating Running Current (A) | 3.85 A |
| Max Current (A) | 7.20 A |
| Cooling Power Input (min-max) (kW) | 0.82 (0.21-1.29) kW |
| Heating Power Input (min-max) (kW) | 0.87 (0.19-1.65) kW |
| Power Supply | Outdoor |
| Sound Levels | |
| Indoor Unit Sound Pressure Noise Level (Cooling) (H / L / Q-Lo) | 44/26/19 dB(A) *Sound pressure level specification is measured accroding to JIS C9612. |
| Indoor Unit Sound Pressure Noise Level (Heating) (H / L / Q-Lo) | 44/29/22 dB(A) *Sound pressure level specification is measured accroding to JIS C9612. |
| Indoor Unit Sound Power Noise Level (Cooling) (H / L / Q-Lo) | 60/42/35 dB(A) |
| Indoor Unit Sound Power Noise Level (Heating) (H / L / Q-Lo) | 60/45/38 dB(A) |
| Outdoor Unit Sound Pressure Noise Level (Cooling) (H / Q-Lo) | 49/44 dB(A) *Sound pressure level specification is measured accroding to JIS C9612. |
| Outdoor Unit Sound Pressure Noise Level (Heating) (H / Q-Lo) | 50/45 dB(A) *Sound pressure level specification is measured accroding to JIS C9612. |
| Outdoor Unit Sound Power Noise Level (Cooling) (H / Q-Lo) | 64/59 dB(A) |
| Outdoor Unit Sound Power Noise Level (Heating) (H / Q-Lo) | 65/60 dB(A) |
| Dimensions & Weight | |
| Indoor Unit Dimensions (H x W x D) (mm) | 290 mm x 779 mm x 209 mm |
| Indoor Unit Net Weight | 8 kg |
| Outdoor Unit Dimensions (H x W x D) | 542 mm x 780 mm x 289 mm |
| Outdoor Unit Net Weight | 31 kg |
| Refrigerant & Piping | |
| Refrigerant Type | R32 |
| Refrigerant Pipe Diameter (Liquid Side) | ø 6.35 mm (1/4 inch) |
| Refrigerant Pipe Diameter (Gas Side) | ø 9.52 mm (3/8 inch) |
| Pipe Extension Length (min-max) | 3 m ~ 20 m |
| Maximum Elevation Length | 15 m |
| Pipe Length for Additional Refrigerant Gas | 7.50 m |
| Pipe Extension (Additional Refrigerant Gas*) | 10 g/m |
| Operating Range | |
| Outdoor Unit Operating Range (Cooling) | -10°C ~ +46°C |
| Outdoor Unit Operating Range (Heating) | -15°C ~ +24°C |
| Other Specifications | |
| Wi-Fi | Optional (Network adaptor required) |
| Long Piping (max.) | 20 m |
| Note | Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. |
Documents & Downloads
✔ 5-Year Panasonic Warranty (residential & commercial) — genuine Panasonic product with full New Zealand warranty support. Warranty details.
Every Panasonic CS-RZ35AKRW sold by NZ Depot is brand new in original packaging and dispatched NZ-wide. Contact NZ Depot for trade pricing or a quote.
Need advice or trade pricing? Contact NZ Depot or browse more heat pump and HVAC deals at NZ Depot.
Pro Tip: Ensure this CS-RZ35AKRW matches your installation. Sourced directly from the Panasonic NZ supply chain for full compatibility and manufacturer warranty.
The NZ Depot Trade Supply Advantage
🏭
No Showroom Markup
Direct trade pricing on every Panasonic unit. You pay for the product, not the overheads.
🚚
Nationwide Dispatch
From Cape Reinga to Bluff. Routed from the nearest distribution hub for fastest delivery.
Downloads and Documents
Trade and Installation FAQ
Is the Panasonic CS-RZ35AKRW – Developer Series 3.5kW High Wall (Unit) suitable for New Zealand conditions?
Yes. The CS-RZ35AKRW is engineered for the climate ranges experienced across New Zealand and is sold and supported by Panasonic NZ.
Does this unit require professional installation?
Yes. To preserve your manufacturer warranty, all refrigerant-based Panasonic equipment must be installed by a licensed New Zealand HVAC technician.
What refrigerant does the CS-RZ35AKRW use?
This unit uses R32 refrigerant, which is the modern, low-GWP standard for residential and light commercial heat pumps in New Zealand.
Looking for the best price on the Panasonic CS-RZ35AKRW? NZ Depot supplies the Panasonic CS-RZ35AKRW New Zealand wide with fast dispatch, trade pricing and genuine Panasonic warranty support. Compare the Panasonic CS-RZ35AKRW – Developer Series 3.5kW High Wall (Unit) with the rest of the Panasonic Developer Series range, check the full specifications above, and order the Panasonic CS-RZ35AKRW online today or request a trade quote for volume supply.
Browse the full range of Panasonic Indoor Units available for NZ-wide trade and retail supply.
© 2026 NZ Depot Limited. All Rights Reserved. | 100% NZ Owned and Operated. | Authorised Panasonic Trade Supplier.
Additional information
| Weight | 8 kg |
|---|---|
| Dimensions | 209 × 779 × 290 mm |
| MPN | |
| Brand | |
| Cooling Capacity (kWs) | |
| Copper Pipe (mm) | |
| Refrigerant | |
| Series | |
| Unit Type | |
| Indoor Subtype |
Only logged in customers who have purchased this product may leave a review.


Reviews
There are no reviews yet