The Super Multi NX outdoor units are capable of efficiently sharing capacity between several indoor units. Each indoor unit can be individually controlled to suit your specific requirements. This means airflow, temperature settings and scheduling can all be adjusted to meet personal preferences, delivering whole house comfort for everyone.
 
A Daikin Multi-Split Heat Pump can heat or cool multiple rooms using only one outdoor unit, and allows individual control of the air conditioning in each room. This not only optimises comfort but saves on running costs by only heating or cooling rooms as required.
 
All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions.
 

DAIKIN 5.2kW SUPER MULTI NX – MULTI SPLIT SYSTEMS R32 Reverse Cycle DC INVERTER CONTROL (Up to 3 Indoor Units) – 3MXM52RVMA

Maximum Connectable Indoor Units: Up to 3 Indoor Units
Model: 3MXM52RVMA
Capacity Class: 5.2 kW
Total Piping Length: 50m
Max Linear Pipe-run (m) (ODU – IDU): 30
Max Height Difference (m): 15
 
<strong>Features</strong>
Key Features
It’s the unique features of Daikin products that makes us the world leader.

Comfort for Everyone

Each indoor unit can be individually controlled, scheduled and set to the desired room temperature ensuring optimal comfort for all occupants.

Controller Features

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Saw Edge Fan Blade
The addition of a saw tooth edge at the rear of the blade smooths airflow over the blade surface, reducing turbulence which in turn results in a quieter, more efficient means of delivering comfort to your home.
 
Compressor
Daikin’s swing compressors are quieter and more efficient than conventional compressors, thanks to their high pressure dome construction and usage of high pressure lubrication oil.
 
Reluctance DC Motor
All Super Multi NX compressors are equipped with Reluctance DC Motors. THese motors utilise the magnetic torque or neodymium magnet in conjunction with reluctance torque, resulting in more energy-efficient operation.
 
Inverter Technology
The Inverter PCB works like the accelerator of a car, gently increasing or decreasing power. This ensures your desired temperature is reached quicker and steadily maintained without fluctuations.
 
<strong>Specification</strong>
 
SPECIFICATIONS   OUTDOOR UNIT                                                                                                                                                                     
Model name Reverse cycle  
3MXM52RVMA 4MXM68RVMA 4MXM80RVMA 5MXM100RVMA  
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz  
Max. connected indoor units capacity kW 9.0 11.0 14.5 15.6  
Casing colour Ivory white  
Compressor type Hermetically sealed swing type  
Refrigerant type R-32  
Outdoor sound pressure level*1 Rated/ Quiet Cooling dB(A) 45/43 47/44 48/45 48/46  
Heating   47/45 48/46 49/47  
Outdoor sound power level H Cooling dB(A) 57 59 60  
Heating   59 60 61  
Dimensions H x W x D mm 695 x 930 x 350 990 x 940 x 320  
Machine weight kg 53 56 61 83  
Outdoor operating range Cooling ˚CDB -10 to 46  
Heating ˚CWB -15 to 18    
Max. piping length m 50 (total) 60 (total) 70 (total) 80 (total)  
30 (for one room)    
Additional charge g/m 20 (for over 40 m)  
Max. level difference m 15 (between indoor and outdoor units) / 7.5 (between indoor units)  
 
Note: *1. The value to the left of the slash is for rated operation. The value to the right is when using Outdoor Unit Quiet Operation.
  INDOOR UNIT                                                                                                                                                                           
Wall-Mounted Type CTXJ-R Series
Model name Reverse cycle  
CTXJ25RVMAW CTXJ25RVMAS CTXJ35RVMAW CTXJ35RVMAS CTXJ50RVMAW CTXJ50RVMAS  
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz  
Front panel colour White Silver White Silver White Silver  
Indoor airflow rate H Cooling l/s 138 (293) 177 (374) 180 (381)  
Heating (cfm) 173 (367) 198 (420) 207 (438)  
Indoor sound pressure level H/L/SL Cooling dB(A) 38/25/21 45/26/22 46/35/32  
Heating   41/28/21 45/29/22 47/35/32  
Indoor sound power level H Cooling dB(A) 52 59 60  
Heating   55 59 61  
Fan speed 5 steps, quiet and automatic  
Temperature control Microcomputer control  
Dimensions H x W x D mm 303 × 998 × 212  
Machine weight kg 12  
Piping connections Liquid (flare) mm ø6.4  
Gas (flare) ø9.5 ø12.7  
Drain ø16.0  
Heat insulation Both liquid and gas pipes  
Wall-Mounted Type CTXM-R Series
Model name Reverse cycle  
CTXM20RVMA CTXM25RVMA CTXM35RVMA CTXM46RVMA  
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz  
Front panel colour White  
Indoor airflow rate H Cooling l/s 155 (328) 173 (367) 188 (399) 203 (431)  
Heating (cfm) 160 (339) 173 (367) 188 (399) 202 (427)  
Indoor sound pressure level H/L/SL Cooling dB(A) 38/25/19 40/25/19 42/26/19 44/35/26  
Heating   39/28/20 40/28/20 42/29/20 43/33/26  
Indoor sound power level H Cooling dB(A) 52 54 56 58  
Heating   53 54 56 57  
Fan speed 5 steps, quiet and automatic  
Temperature control Microcomputer control  
Dimensions H x W x D mm 285 x 770 x 223  
Machine weight kg 9  
Piping connections Liquid (flare) mm ø6.4  
Gas (flare) ø9.5 ø12.7  
Drain ø16.0  
Heat insulation Both liquid and gas pipes  
Model name Reverse cycle  
CTXM50RVMA CTXM60RVMA CTXM71RVMA CTXM85RVMA CTXM95RVMA  
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz  
Front panel colour White  
Indoor airflow rate H Cooling l/s 282 (597) 325 (689) 333 (706) 398 (844) 400 (848)  
Heating (cfm) 287 (607) 333 (706) 328 (696) 422 (893) 413 (876)  
Indoor sound pressure level H/L/SL Cooling dB(A) 45/35/28 48/36/29 49/37/30 51/40/37 53/42/38  
Heating   45/33/28 48/33/29 49/35/30 51/38/35 52/38/35  
Indoor sound power level H Cooling dB(A) 59 62 63 65 67  
Heating   59 62 63 65 66  
Fan speed 5 steps, quiet and automatic  
Temperature control Microcomputer control  
Dimensions H x W x D mm 295 x 990 x 263 340 x 1,200 x 259  
Machine weight kg 13 17 18  
Piping connections Liquid (flare) mm ø6.4  
Gas (flare) ø12.7 ø15.9  
Drain ø16.0  
Heat insulation Both liquid and gas pipes  
SPECIFICATIONS (CONT) Duct-Connected Type CDXP-R and CDXM-R Series
Model name Reverse cycle  
CDXP25RVMA CDXP35RVMA CDXM25RVMA CDXM35RVMA CDXM50RVMA CDXM60RVMA CDXM71RVMA  
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz  
Indoor airflow rate H Cooling l/s 145 (307) 158 (335) 167 (353) 200 (424) 267 (565)  
Heating (cfm) 145 (307) 158 (335) 167 (353) 200 (424) 267 (565)  
Indoor sound pressure level*1 H/L/SL Cooling dB(A) 35/31/29 37/33/31 38/34/32  
Heating   35/31/29 37/33/31 38/34/32  
Indoor sound power level H Cooling dB(A) 49 51 52  
Heating   49 51 52  
Fan speed 5 steps, quiet and automatic  
Temperature control Microcomputer control  
Dimensions H x W x D mm 200 x 700 x 620 200 x 900 x 620 200 x 1,100 x 620  
Machine weight kg 21 25 27 30  
Piping connections Liquid (flare) mm ø6.4  
Gas (flare) ø9.5 ø12.7 ø15.9  
Drain VP 20 (Inside diameter ø20, Outside diameter ø26)  
Heat insulation Both liquid and gas pipes  
External static pressure 30 40  
 
Note: *1. The values are for the rear-suction inlet of the CDXP-R at an external static pressure of 30 Pa. Values for the bottom-suction inlet can be obtained by adding 6 dB(A). The values are for the rear-suction inlet of the CDXM-R at an external static pressure of 40 Pa. Values for the bottom-suction inlet can be obtained by adding 5 dB(A). When a duct-connected type indoor unit with a reduced external static pressure is installed, values for the bottom-suction inlet are higher.
Duct-Connected Type FMA-R Series
Model name Reverse cycle                          
FMA50RVMA FMA60RVMA FMA71RVMA                          
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz                          
Indoor airflow rate H Cooling l/s 300 383                          
Heating   300                                                383                          
Indoor sound pressure level H/L Cooling dB(A) 35/31 38/33                          
Heating   35/31                                             38/33                          
Indoor sound power level H Cooling dB(A) 49 52                          
Heating   49                                                  52                          
Fan speed 3 steps                          
Temperature control                          
Dimensions H x W x D mm 245 x 1,000 x 800                          
Machine weight kg 37                          
Piping connections Liquid (flare)   ø6.4                          
Gas (flare) mm ø12.7 ø15.9                          
Drain   VP 25 (Inside diameter ø25, Outside diameter ø32)                          
Heat insulation                          
External static pressure Rated Pa 50 (50-150*1)                          
Note: *1. External static pressure is changeable in 11 stages by remote controller.
Ceiling-Mounted Cassette Type
Model name Reverse cycle                          
FFA25RV1A FFA35RV1A FFA50RV1A FFA60RV1A                          
Power supply 1 phase, 220-240 V, 50 Hz                          
Indoor airflow rate H Cooling l/s 150 (318) 167 (353) 200 (424) 250 (530)                          
Heating (cfm) 150 (318) 167 (353) 200 (424) 250 (530)                          
Indoor sound pressure level H/L Cooling dB(A) 33/27 36/29 38/30 42/34                          
Heating   33/27 36/28 38/28 42/34                          
Indoor sound power level H Cooling dB(A) 46 49 51 55                          
Heating   46 49 51 55                          
Fan speed 2 steps                          
Temperature control Microcomputer control                          
dimensions H x W x D mm 286 x 575 x 575                          
Machine weight kg 17.5                          
Piping connections Liquid (flare)   ø6.4                          
Gas (flare) mm ø9.5 ø12.7                          
Drain   VP 20 (Inside diameter ø20, Outside diameter ø26)                          
Heat insulation Both liquid and gas pipes                          
Measurement conditions 1. Cooling operation data is based on the following conditions: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5 m. 2. Heating operation data is based on the following conditions: indoor temp. 20˚CDB; outdoor temp. 7˚CDB, 6˚CWB; piping length 5 m. 3. Sound pressure levels are measured in an anechoic chamber based on temperature conditions 1 and 2 above. These values are normally somewhat higher during actual operation as a result of ambient conditions.                    
OPTIONS
 
  OUTDOOR UNIT                                                                                                                                                                     
No. Item 4MKM68R 4MXM68R 4MKM80R 4MXM80R 5MKM100R 5MXM100R  
1 Air direction adjustment grille KPW5E112  
2 Drain plug KKP937A4*1 KKP945A4*2  
3 Demand response enabling device BRP070A46 BRP070A42  
Notes: *1. One set includes five pieces for five units. *2. One set includes one piece for one unit.
  INDOOR UNIT
No. Item Wall-Mounted Type  
CTXJ25/35/50R CTXM20/25/35/46R CTXM50/60/71R CTXM85/95R  
1 Wired remote controller                                                     *1 BRC073A4 BRC073A4*2 BRC073A4*3 BRC073A4  
2 Wired remote controller cord (shielded wire) Length of 3 m BRCW901A03  
Length of 8 m BRCW901A08  
3 Daikin Mobile Controller BRP072A42 BRP072A42*2 BRP072A42*3 BRP072A42  
4 Wiring adaptor for time clock / remote controller               *4 (Normal open pulse contact / normal open contact) KRP413AB1S KRP413AB1S*2 KRP413AB1S*3 KRP413AB1S  
5 Titanium apatite deodorising filter                                      *5 KAF970A46 KAF970A48  
6 Dust collection filter BAFP046A41 BAFP046A41*6  
7 Wireless remote controller loss prevention with chain KKF910A4  
8 Remote control PC-board set KRP067A41 KRP980B2  
Notes: *1. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally.
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *3. A remote control PC-board set (KRP980B2) is also required for each indoor unit. Notes: *1. A wireless receiver kit (BRC086A2R1) is also required for each indoor unit. *5. The filter is a standard accessory. *6. Two pieces are required for these models. *3. The wiring for the wired remote controller should be obtained locally.
No. Item Duct-Connected Type  
CDXP25/35R CDXM25/35/50R CDXM60/71R FMA50/60/71R  
1 Wireless remote controller Cooling only use BRC086A12 BRC086A22*1  
Reverse cycle use BRC086A11 BRC086A21*1  
2 Wireless receiver kit BRC086A2R1  
3 Wired remote controller BRC073A4*2 BRC1E62*3  
4 Wired remote controller cord (shielded wire) Length of 3 m BRCW901A03  
Length of 8 m BRCW901A08  
5 Wiring adaptor for time clock / remote controller              *4 (Normal open pulse contact / normal open contact) KRP413AB1S  
6 Wireless remote controller loss prevention with chain KKF910A4  
7 Insulation kit for high humidity KDT25N32 KDT25N50 KDT25N63  
8 Remote sensor KRCS01-4B  
9 High efficiency filter 65% KAFP632B80  
90% KAFP633B80  
10 Long-life filter KAFP631B80  
11 Filter chamber KDDFP63B80  
12 Service panel White KTBJ25K80W  
Fresh white KTBJ25K80F  
Brown KTBJ25K80T  
13 Air discharge adaptor KDAP25A71A  
14 Shield plate for side plate KDBD63A160  
*2. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally.
No. Item Ceiling-Mounted Cassette Type  
1 Decoration panel BYFQ60B3W1  
2 Wireless remote controller Cooling only use BRC086A22  
Reverse cycle use BRC086A21  
3 Wireless receiver kit BRC086A2R2  
4 Wired remote controller                                                          *2 BRC1E62  
5 Wireless remote controller loss prevention with chain KKF910A4  
6 Remote sensor KRCS01-1B  
7 Sealing member of air discharge outlet KDBH44BA60  
8 Panel spacer KDBQ44BA60A  
9 Replacement long-life filter KAFQ441BA60  
10 Fresh air intake kit KDDQ44XA60  
Notes: *1. A wireless receiver kit (BRC086A2R2) is also required for each indoor unit. *2. The wiring for wired remote controller should be obtained locally.
  CONTROL SYSTEM                                                                                                                                                              
No. Item Wall-Mounted Type Duct-Connected Type Ceiling-Mounted Cassette Type  
CTXJ25/35/50R CTXM20/25/35/46R CTXM50/60/71R CTXM85/95R CDXP-R, CDXM-R FMA-R  
1 Central remote controller DCS302CA61*1 DCS302CA61 DCS302CA61*2  
2 Unified On/Off controller DCS301BA61*1 DCS301BA61 DCS301BA61*2  
3 Schedule timer DST301BA61*1 DST301BA61 DST301BA61*2  
4 Interface adaptor for DIII-NET use KRP928BB2S KRP928BB2S*3 KRP928BB2S*4 KRP928BB2S DTA112BA51  
5 Remote control PC-board set KRP067A41 KRP980B2  
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. *2. An interface adaptor for DIII-NET use (DTA112BA51) is also required for each indoor unit. *3. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *4. A remote control PC-board set (KRP980B2) is also required for each indoor unit.

 

<strong>Warranty & Downloads</strong>
Daikin 5 Years Warranty - NZDEPOT
 
 
 
Daikin’s 5-year parts and labour warranty applies to split, multi-split and ducted heat pumps purchased and installed in homes across New Zealand 5 Year Warranty

Installation & Warranty Claims Note:

Installation must be undertaken by a professional licensed Aircon technician or/and Electrician.

Additional information

Weight 15 kg
Dimensions 275 × 1100 × 299 mm

Main Menu