Line Components

  • $54.99$99.98
  • $54.99$99.98
  • $54.99$99.98
  • $54.99$99.98
  • $43.99$79.98
  • $43.99$79.98
  • Freddox Filter Drier Solid Core Dsc032S 1/4″ Odf FD032S | Line Components

    Freddox filter driers offer a high level of protection for refrigeration and air-conditioning systems liquid Line. They are specifically designed to capture and retain moisture and solid particles from circulating throughout the system, which can create acid that causes damage to the compressor and other components piped within the circuit. Freddox driers are available in version to be brazed (DSC S), or screwed with male/male (DSC) or female/male (DSC FM) SAE connexions to answer every configuration of installations .

    $43.99$79.98
  • Freddox Filter Drier Solid Core Dsc032 1/4″ Sae FD032 | Line Components

    Freddox filter driers offer a high level of protection for refrigeration and air-conditioning systems liquid Line. They are specifically designed to capture and retain moisture and solid particles from circulating throughout the system, which can create acid that causes damage to the compressor and other components piped within the circuit. Freddox driers are available in version to be brazed (DSC S), or screwed with male/male (DSC) or female/male (DSC FM) SAE connexions to answer every configuration of installations .

    $43.99$79.98
  • Parker Flocon A82-54 – Epr, 2-5/8 F.Sw Conn, 2-1/8 Port 102927 | Line Components

    The A8 has a unique modular design that allows the commercial pressure regulator to be soldered into the line without disassembly, yet provides full access for disassembly, cleaning and servicing from the top only. Interchangeable capacity cartridges facilitate flow revisions should an undersized or oversized condition be created, while pilot adaptors can be changed out to add features or even change functions. Thus, retrofitting for additional evaporator capacity, heat reclaim, or hold back for hot gas defrost is simple and requires no pipe line revisions under most circumstances. These valves will modulate to maintain a pressure as set for in the field, in spite of fluctuations in load, changes in ambient, changes in available refrigerant flow paths, and other operating variances. Appropriately sized, these valves will modulate the flow of liquid or vapor, high side or low side in a wide variety of system arrangements used in industrial, commercial and air conditioning installations. Models are available in combinations of connection sizes, port sizes, functions and features as designated by the model code, for application in a wide variety of control functions on industrial, commercial and air conditioning systems.Three control functions are available:Inlet, Outlet, and Differential pressure control. Two control features can be added by incorporating pilot solenoids; either Electric Shut-Off(S) or Electric Bypass (B); also called Wide-Opening.The valves are an integrated assembly of four modules:1) A body, which contains no moving parts, but is ordered to suit a particular connection size;2) A capacity cartridge, which contains both piston and modulating plug, and defines the Port Size;3) A pilot adapter, which defines the valve function and onto which the Pilot Solenoids providing either the “S” or “B” feature are added as required;4) The bonnet, containing the Range Spring and adjustment screw, which mechanisms are set for the value of pressure which the valve is to maintain

    $7,083.99$12,879.98
  • Parker Flocon A82-42 – Epr, 2-1/8 F.Sw Conn, 1-5/8 Port 102923 | Line Components

    The A8 has a unique modular design that allows the commercial pressure regulator to be soldered into the line without disassembly, yet provides full access for disassembly, cleaning and servicing from the top only. Interchangeable capacity cartridges facilitate flow revisions should an undersized or oversized condition be created, while pilot adaptors can be changed out to add features or even change functions. Thus, retrofitting for additional evaporator capacity, heat reclaim, or hold back for hot gas defrost is simple and requires no pipe line revisions under most circumstances. These valves will modulate to maintain a pressure as set for in the field, in spite of fluctuations in load, changes in ambient, changes in available refrigerant flow paths, and other operating variances. Appropriately sized, these valves will modulate the flow of liquid or vapor, high side or low side in a wide variety of system arrangements used in industrial, commercial and air conditioning installations. Models are available in combinations of connection sizes, port sizes, functions and features as designated by the model code, for application in a wide variety of control functions on industrial, commercial and air conditioning systems.Three control functions are available:Inlet, Outlet, and Differential pressure control. Two control features can be added by incorporating pilot solenoids; either Electric Shut-Off(S) or Electric Bypass (B); also called Wide-Opening.The valves are an integrated assembly of four modules:1) A body, which contains no moving parts, but is ordered to suit a particular connection size;2) A capacity cartridge, which contains both piston and modulating plug, and defines the Port Size;3) A pilot adapter, which defines the valve function and onto which the Pilot Solenoids providing either the “S” or “B” feature are added as required;4) The bonnet, containing the Range Spring and adjustment screw, which mechanisms are set for the value of pressure which the valve is to maintain

    $6,588.99$11,979.98
  • Parker Flocon A82-42 – Epr, 1-5/8 F.Sw Conn, 1-5/8 Port 102920 | Line Components

    The A8 has a unique modular design that allows the commercial pressure regulator to be soldered into the line without disassembly, yet provides full access for disassembly, cleaning and servicing from the top only. Interchangeable capacity cartridges facilitate flow revisions should an undersized or oversized condition be created, while pilot adaptors can be changed out to add features or even change functions. Thus, retrofitting for additional evaporator capacity, heat reclaim, or hold back for hot gas defrost is simple and requires no pipe line revisions under most circumstances. These valves will modulate to maintain a pressure as set for in the field, in spite of fluctuations in load, changes in ambient, changes in available refrigerant flow paths, and other operating variances. Appropriately sized, these valves will modulate the flow of liquid or vapor, high side or low side in a wide variety of system arrangements used in industrial, commercial and air conditioning installations. Models are available in combinations of connection sizes, port sizes, functions and features as designated by the model code, for application in a wide variety of control functions on industrial, commercial and air conditioning systems.Three control functions are available:Inlet, Outlet, and Differential pressure control. Two control features can be added by incorporating pilot solenoids; either Electric Shut-Off(S) or Electric Bypass (B); also called Wide-Opening.The valves are an integrated assembly of four modules:1) A body, which contains no moving parts, but is ordered to suit a particular connection size;2) A capacity cartridge, which contains both piston and modulating plug, and defines the Port Size;3) A pilot adapter, which defines the valve function and onto which the Pilot Solenoids providing either the “S” or “B” feature are added as required;4) The bonnet, containing the Range Spring and adjustment screw, which mechanisms are set for the value of pressure which the valve is to maintain

    $5,532.99$10,059.98
  • Parker Flocon A81-35 – Epr, 1-5/8 F.Sw Conn, 1-3/8 Port 101722 | Line Components

    The A8 has a unique modular design that allows the commercial pressure regulator to be soldered into the line without disassembly, yet provides full access for disassembly, cleaning and servicing from the top only. Interchangeable capacity cartridges facilitate flow revisions should an undersized or oversized condition be created, while pilot adaptors can be changed out to add features or even change functions. Thus, retrofitting for additional evaporator capacity, heat reclaim, or hold back for hot gas defrost is simple and requires no pipe line revisions under most circumstances. These valves will modulate to maintain a pressure as set for in the field, in spite of fluctuations in load, changes in ambient, changes in available refrigerant flow paths, and other operating variances. Appropriately sized, these valves will modulate the flow of liquid or vapor, high side or low side in a wide variety of system arrangements used in industrial, commercial and air conditioning installations. Models are available in combinations of connection sizes, port sizes, functions and features as designated by the model code, for application in a wide variety of control functions on industrial, commercial and air conditioning systems.Three control functions are available:Inlet, Outlet, and Differential pressure control. Two control features can be added by incorporating pilot solenoids; either Electric Shut-Off(S) or Electric Bypass (B); also called Wide-Opening.The valves are an integrated assembly of four modules:1) A body, which contains no moving parts, but is ordered to suit a particular connection size;2) A capacity cartridge, which contains both piston and modulating plug, and defines the Port Size;3) A pilot adapter, which defines the valve function and onto which the Pilot Solenoids providing either the “S” or “B” feature are added as required;4) The bonnet, containing the Range Spring and adjustment screw, which mechanisms are set for the value of pressure which the valve is to maintain

    $4,135.99$7,519.98
  • Parker Flocon A81-28 – Epr, 1-3/8 F.Sw Conn, 1-1/8 Port 101717 | Line Components

    The A8 has a unique modular design that allows the commercial pressure regulator to be soldered into the line without disassembly, yet provides full access for disassembly, cleaning and servicing from the top only. Interchangeable capacity cartridges facilitate flow revisions should an undersized or oversized condition be created, while pilot adaptors can be changed out to add features or even change functions. Thus, retrofitting for additional evaporator capacity, heat reclaim, or hold back for hot gas defrost is simple and requires no pipe line revisions under most circumstances. These valves will modulate to maintain a pressure as set for in the field, in spite of fluctuations in load, changes in ambient, changes in available refrigerant flow paths, and other operating variances. Appropriately sized, these valves will modulate the flow of liquid or vapor, high side or low side in a wide variety of system arrangements used in industrial, commercial and air conditioning installations. Models are available in combinations of connection sizes, port sizes, functions and features as designated by the model code, for application in a wide variety of control functions on industrial, commercial and air conditioning systems.Three control functions are available:Inlet, Outlet, and Differential pressure control. Two control features can be added by incorporating pilot solenoids; either Electric Shut-Off(S) or Electric Bypass (B); also called Wide-Opening.The valves are an integrated assembly of four modules:1) A body, which contains no moving parts, but is ordered to suit a particular connection size;2) A capacity cartridge, which contains both piston and modulating plug, and defines the Port Size;3) A pilot adapter, which defines the valve function and onto which the Pilot Solenoids providing either the “S” or “B” feature are added as required;4) The bonnet, containing the Range Spring and adjustment screw, which mechanisms are set for the value of pressure which the valve is to maintain

    $3,904.99$7,099.98
  • $934.99$1,699.98
  • $87.99$159.98
  • $76.99$139.98
  • Alco Ex8 U31 Electronic Valve 1-3/8 X 1-3/8 EX8-U21 | Line Components

    Features• Fully hermetic stainless steel design• Fast full stroke time• Ceramic slide and port for accurate flow and minimal wear• High resolution and excellent repeatability• Bi-directional versions for heat pump applications• Positive shut-off function to eliminate the use of an additional solenoid valve• Linear flow capacity• Wide capacity range (10 – 100%)• Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuit• Direct coupling of motor and valve for high reliability (no gear mechanism)• Applicable to all common A1,A2L,A3 refrigerants, including subcritical CO2

    $1,891.99$3,439.98
  • Alco Ex 7 U31 Electronic Valve 1-3/8 X 1-3/8 EX7-U31 | Line Components

    The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems.. Multifunction capability as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid line actuator and other applications systems..

    $1,165.99$2,119.98
  • Alco Ex 5-U31 Electronic Valve 7/8 X 7/8 EX5-U31 | Line Components

    Fully hermetic designFast full stroke timeApplicable to all common refrigerants (HCFC, HFC), for subcritical CO2 applicationsHigh resolution and excellent repeatabilityBi-directional versions for heat pump applicationsPositive shut-off function to eliminate the use of an additional solenoid valveLinear flow capacityWide capacity range (10 – 100%)Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuitDirect coupling of motor and valve for high reliability (no gear mechanism) The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems.. Multifunction capability as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid line actuator and other applications systems..

    $1,055.99$1,919.98
  • Alco Ex 4-31 Electronic Valve 5/8 X 5/8 EX4-U31 | Line Components

    Fully hermetic designFast full stroke timeApplicable to all common refrigerants (HCFC, HFC), for subcritical CO2 applicationsHigh resolution and excellent repeatabilityBi-directional versions for heat pump applicationsPositive shut-off function to eliminate the use of an additional solenoid valveLinear flow capacityWide capacity range (10 – 100%)Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuitDirect coupling of motor and valve for high reliability (no gear mechanism) The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems.. Multifunction capability as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid line actuator and other applications systems..

    $1,000.99$1,819.98
  • $98.99$179.98
  • $417.99$759.98
  • $164.99$299.98
  • $1,539.99$2,799.98

Main Menu