  • Invensys – Ranco Oil Failure Switches (Without Capillary) P30-5827-57 P30-5827-57 | Oil Management

    P30 Series Lube Oil ControlsThese lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure. If adequate oil pressure is lost, the built-in P30 Time Delay Switch starts timing. If the oil pressure does not recover within the set period, the control circuit is opened, stopping the compressor. These controls also feature replaceable time delay modules, Super Cap® capillary protection system, front-located captive cover screw and adjustable pressure range (P30-3000 models only).

    $670.99$1,219.98
  • Invensys – Ranco Oil Failure Controller Ranco 120 Sec Delay P30-3801 | Oil Management

    P30-3801P30 Series Lube Oil ControlsThe Ranco® P30 Series Lube Oil Protection Controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure. This control utilizes the built-in P30 Time Delay Switch to start timing when oil pressure drops below operating requirements. The timer is designed not only to track oil pressure recovery within a set period, but also to alert the control circuit to open and stop the compressor when the recovery period is exceeded. These controls also feature replaceable time delay modules, Super Cap® capillary protection system and front-located captive cover screw.Features and BenefitsAlarm circuit standardAmbient temperature compensatedSuper Cap® capillary protection systemHigh impact, non-conductive coverField replaceable switch moduleManual resetIndustry standard circuitry and terminal identification

    $582.99$1,059.98
  • Invensys – Ranco Oil Failure Control P30-5827 P30-5827 | Oil Management

    P30-5827HP30 Series Lube Oil ControlsThese lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure. If adequate oil pressure is lost, the built-in P30 Time Delay Switch starts timing. If the oil pressure does not recover within the set period, the control circuit is opened, stopping the compressor. These controls also feature replaceable time delay modules, Super Cap® capillary protection system, front-located captive cover screw and adjustable pressure range (P30-3000 models only).

    $527.99$959.98
  • Henry Technologies Henry Oil Filter 3/8″ Ods S-4005 | Oil Management

    Henry Oil Filter/Drier 3/8MSAEThe function of an Oil Filter is to remove system debris from the refrigerantoil. The function of an Oil Filter Drier is to remove both system debris andmoisture from the refrigerant oil. Their purpose is to protect compressors andoil level regulators from damage.ApplicationsThe Henry Technologies S-4004 oil filter and S-4005 oil filter drier can beused in both Low and High Pressure Oil Management Systems. Models aresuitable for HCFC and HFC refrigerants along with their associated oils.The unique drying features of the S-4005 model are particularly suited forsystems using POE oil. This type of oil is more hydroscopic than mineral oil.This means that POE oil absorbs moisture at a much higher rate. Moisturein a refrigeration system can produce problems and/or harmful conditions.One S-4004 or S-4005 model can be fitted in the oil return line between theoil separator and oil reservoir, instead of fitting one oil strainer per oil levelregulator. These models will also remove more debris than traditional oilstrainers.Main FeaturesS-4005 and SH-4005 models• High flow capacity with low pressure drop• Large filter area• Micronic filtration• High level of drying• Eliminates the need to fit individual oil return line strainersTechnical SpecificationS-4005 modelAllowable operating pressure = 0 to 31 bargAllowable operating temperature = -10oC to +100o CFilter surface area = 3000 cm2Filter particle retention = 6 micronDrier = 131cm3 of XH9 desiccant SH-4005 modelSame as S-4005, except it has a higher operatingpressure.Allowable operating pressure = 0 to 45 barg

    $560.99$1,019.98
  • Henry Technologies Henry 3/8″ Flare Oil Strainer SH9105 | Oil Management

    Henry Oil Line Strainer 3/8 MSAEThe Henry Technologies SH-9105 oil strainer can be used in both Low andHigh Pressure Oil Management Systems. The strainer is suitable for HCFCand HFC refrigerants, along with their associated oils.Although the strainer is compatible with HFC/POE refrigerant/oil combinations,Henry Technologies recommends the use of an oil filter or oil filter-drier. Thisis due to the scavenging nature of POE oil.Greater system protection will be achieved using an oil filter or oil filter driersover a traditional oil strainers.Typically, an oil strainer is fitted immediately upstream of a mechanical oillevel regulator in order to protect the float needle valve from debris. This inturn protects the compressor from damage.

    $153.99$279.98
  • $3,761.99$6,839.98
  • Parker Tko Acid Test Kit TKO | Lubricants

    Parker Hannifin Acid TestOne bottle test kit is a simple and cost effective method of determining whether the acid level is within an acceptable range for mineral or alkylbenzene lubricants. Simply fill the bottle with oil to the line on bottle neck and shake.Features:Ultra-sensitive color change guarantees an accurate test, marginal conditions cause partialcolor changesIf the test remains purple, oil is safe. If it turns yellow, acid is too highFor use with mineral and alkylbenzenelubricantsColor comparison chart in every boxInexpensive to use – billable test