No products in the cart.
Alco
-
$1,088.99
$1,979.98Alco Trax Oil Om3 – Base Unit – 120 Sec Delay OM3-120 | Oil Management
$1,088.99$1,979.98 -
$1,121.99
$2,039.98Alco Trax Oil Om3 – Base Unit OM3-020 | Oil Management
$1,121.99$2,039.98 -
Alco Trax Oil Adaptor – 3 Bolt Flange – D2 To D6 / Stream / 4-6 C ADP301 | Oil Management
Trax Oil adaptor to suit D2 to D6 / Stream / 4-6 C
$142.99$259.98 -
Alco Tx Valve Orifice T10-000 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Tx Valve Orifice T10-000 | Line Components
$65.99$119.98 -
Alco Tx Valve External Eq Flare R134 TIE-MW | Line Components
With interchangeable nozzles. All valves are factory set to a static superheat of 3.3 K and normally no readjustment is needed. Power range 0.25 – 19 kW. Connection: 3/8″ flare x 1/2″ flare.
$241.99$439.98 -
Alco Thermo Valve Cage Alco T10-004 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-004 | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-005 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-005 | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-002 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-002 | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-001 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-001 | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-006 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-006 | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-00X | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-00X | Line Components
$65.99$119.98 -
Alco Thermo Valve Cage Alco T10-003 | Line Components
The nominal cooling capacity kW is given at an evaporating temperature of +4°C, a condensing temperature of +38°C and 1 K subcooling at the inlet of the expansion valve. Note: When sizing an expansion valve for a refrigerant with glide e.g. R407C, it is important to specify evaporating temperature as dew point = saturated gas and condensing temperature as bubble point = saturated liquid.
$65.99$119.98Alco Thermo Valve Cage Alco T10-003 | Line Components
$65.99$119.98 -
Alco Thermo Valve Body Internal Eq. Sw. Conn R407F/R407C TIS-NW | Line Components
With interchangeable nozzles. All valves are factory set to a static superheat of 3.3 K and normally no readjustment is needed. Power range 0.25 – 19 kW. Connection: 3/8″ flare x 1/2″ solder.
$208.99$379.98 -
Alco Thermo Valve Body Internal Eq. Sw. Conn R404A Alco TIS-SW | Line Components
With interchangeable nozzles. All valves are factory set to a static superheat of 3.3 K and normally no readjustment is needed. Power range 0.25 – 19 kW. Connection: 3/8″ flare x 1/2″ solder.
$208.99$379.98 -
Alco Thermo Valve Body Internal Eq. Sw. Conn R134A Alco TIS-MW | Line Components
With interchangeable nozzles. All valves are factory set to a static superheat of 3.3 K and normally no readjustment is needed. Power range 0.25 – 19 kW. Connection: 3/8″ flare x 1/2″ solder.
$208.99$379.98 -
Alco Thermo Valve Body Internal Eq. R134A Alco TI-MW | Line Components
With interchangeable nozzles. All valves are factory set to a static superheat of 3.3 K and normally no readjustment is needed. Power range 0.25 – 19 kW. Connection: 3/8″ flare x 1/2″ flare.
$208.99$379.98