...

Daikin 6.8kW R32 Super Multi NX RC ODU ā€“ 4MXM68RVMA

$3,394.86$6,789.72 Incl GST (-50%)

Out of stock

Daikin Logo - Nzdepot

The Super Multi NX outdoor units are capable of efficiently sharing capacity between several indoor units. Each indoor unit can be individually controlled to suit your specific requirements. This means airflow, temperature settings and scheduling can all be adjusted to meet personal preferences, delivering whole house comfort for everyone.
Ā 
A Daikin Multi-Split Heat Pump can heat or cool multiple rooms using only one outdoor unit, and allows individual control of the air conditioning in each room. This not only optimises comfort but saves on running costs by only heating or cooling rooms as required.
Ā 
All Daikin air conditioners exceed MEPS requirements, in line with Daikinā€™s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions.
Ā 

DAIKIN 6.8kW SUPER MULTI NX ā€“ MULTI SPLIT SYSTEMS R32 Reverse Cycle DC INVERTER CONTROL (Up to 4 Indoor Units) ā€“ 4MXM68RVMA

Maximum Connectable Indoor Units: Up to 3 Indoor Units
Model: 4MXM68RVMA
Capacity Class: 6.8 kW
Total Piping Length: 60m
Max Linear Pipe-run (m) (ODU ā€“ IDU): 30
Max Height Difference (m): 15
Ā 
Features
Key Features
Itā€™s the unique features of Daikin products that makes us the world leader.

Comfort for Everyone

Each indoor unit can be individually controlled, scheduled and set to the desired room temperature ensuring optimal comfort for all occupants.

Controller Features

Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Ā 
Saw Edge Fan Blade
The addition of a saw tooth edge at the rear of the blade smooths airflow over the blade surface, reducing turbulence which in turn results in a quieter, more efficient means of delivering comfort to your home.
Ā 
Compressor
Daikinā€™s swing compressors are quieter and more efficient than conventional compressors, thanks to their high pressure dome construction and usage of high pressure lubrication oil.
Ā 
Reluctance DC Motor
All Super Multi NX compressors are equipped with Reluctance DC Motors. THese motors utilise the magnetic torque or neodymium magnet in conjunction with reluctance torque, resulting in more energy-efficient operation.
Ā 
Inverter Technology
The Inverter PCB works like the accelerator of a car, gently increasing or decreasing power. This ensures your desired temperature is reached quicker and steadily maintained without fluctuations.
Specification
Ā 
SPECIFICATIONS Ā  OUTDOOR UNITĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
Model name Reverse cycle Ā 
3MXM52RVMA 4MXM68RVMA 4MXM80RVMA 5MXM100RVMA Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā 
Max. connected indoor units capacity kW 9.0 11.0 14.5 15.6 Ā 
Casing colour Ivory white Ā 
Compressor type Hermetically sealed swing type Ā 
Refrigerant type R-32 Ā 
Outdoor sound pressure level*1 Rated/ Quiet Cooling dB(A) 45/43 47/44 48/45 48/46 Ā 
Heating Ā  47/45 48/46 49/47 Ā 
Outdoor sound power level H Cooling dB(A) 57 59 60 Ā 
Heating Ā  59 60 61 Ā 
Dimensions H x W x D mm 695 x 930 x 350 990 x 940 x 320 Ā 
Machine weight kg 53 56 61 83 Ā 
Outdoor operating range Cooling ĖšCDB -10 to 46 Ā 
Heating ĖšCWB -15 to 18 Ā  Ā 
Max. piping length m 50 (total) 60 (total) 70 (total) 80 (total) Ā 
30 (for one room) Ā  Ā 
Additional charge g/m 20 (for over 40 m) Ā 
Max. level difference m 15 (between indoor and outdoor units) / 7.5 (between indoor units) Ā 
Ā 
Note: *1. The value to the left of the slash is for rated operation. The value to the right is when using Outdoor Unit Quiet Operation.
Ā  INDOOR UNITĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
Wall-Mounted Type CTXJ-R Series
Model name Reverse cycle Ā 
CTXJ25RVMAW CTXJ25RVMAS CTXJ35RVMAW CTXJ35RVMAS CTXJ50RVMAW CTXJ50RVMAS Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā 
Front panel colour White Silver White Silver White Silver Ā 
Indoor airflow rate H Cooling l/s 138 (293) 177 (374) 180 (381) Ā 
Heating (cfm) 173 (367) 198 (420) 207 (438) Ā 
Indoor sound pressure level H/L/SL Cooling dB(A) 38/25/21 45/26/22 46/35/32 Ā 
Heating Ā  41/28/21 45/29/22 47/35/32 Ā 
Indoor sound power level H Cooling dB(A) 52 59 60 Ā 
Heating Ā  55 59 61 Ā 
Fan speed 5 steps, quiet and automatic Ā 
Temperature control Microcomputer control Ā 
Dimensions H x W x D mm 303 Ɨ 998 Ɨ 212 Ā 
Machine weight kg 12 Ā 
Piping connections Liquid (flare) mm Ćø6.4 Ā 
Gas (flare) Ćø9.5 Ćø12.7 Ā 
Drain Ćø16.0 Ā 
Heat insulation Both liquid and gas pipes Ā 
Wall-Mounted Type CTXM-R Series
Model name Reverse cycle Ā 
CTXM20RVMA CTXM25RVMA CTXM35RVMA CTXM46RVMA Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā 
Front panel colour White Ā 
Indoor airflow rate H Cooling l/s 155 (328) 173 (367) 188 (399) 203 (431) Ā 
Heating (cfm) 160 (339) 173 (367) 188 (399) 202 (427) Ā 
Indoor sound pressure level H/L/SL Cooling dB(A) 38/25/19 40/25/19 42/26/19 44/35/26 Ā 
Heating Ā  39/28/20 40/28/20 42/29/20 43/33/26 Ā 
Indoor sound power level H Cooling dB(A) 52 54 56 58 Ā 
Heating Ā  53 54 56 57 Ā 
Fan speed 5 steps, quiet and automatic Ā 
Temperature control Microcomputer control Ā 
Dimensions H x W x D mm 285 x 770 x 223 Ā 
Machine weight kg 9 Ā 
Piping connections Liquid (flare) mm Ćø6.4 Ā 
Gas (flare) Ćø9.5 Ćø12.7 Ā 
Drain Ćø16.0 Ā 
Heat insulation Both liquid and gas pipes Ā 
Model name Reverse cycle Ā 
CTXM50RVMA CTXM60RVMA CTXM71RVMA CTXM85RVMA CTXM95RVMA Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā 
Front panel colour White Ā 
Indoor airflow rate H Cooling l/s 282 (597) 325 (689) 333 (706) 398 (844) 400 (848) Ā 
Heating (cfm) 287 (607) 333 (706) 328 (696) 422 (893) 413 (876) Ā 
Indoor sound pressure level H/L/SL Cooling dB(A) 45/35/28 48/36/29 49/37/30 51/40/37 53/42/38 Ā 
Heating Ā  45/33/28 48/33/29 49/35/30 51/38/35 52/38/35 Ā 
Indoor sound power level H Cooling dB(A) 59 62 63 65 67 Ā 
Heating Ā  59 62 63 65 66 Ā 
Fan speed 5 steps, quiet and automatic Ā 
Temperature control Microcomputer control Ā 
Dimensions H x W x D mm 295 x 990 x 263 340 x 1,200 x 259 Ā 
Machine weight kg 13 17 18 Ā 
Piping connections Liquid (flare) mm Ćø6.4 Ā 
Gas (flare) Ćø12.7 Ćø15.9 Ā 
Drain Ćø16.0 Ā 
Heat insulation Both liquid and gas pipes Ā 
SPECIFICATIONS (CONT) Duct-Connected Type CDXP-R and CDXM-R Series
Model name Reverse cycle Ā 
CDXP25RVMA CDXP35RVMA CDXM25RVMA CDXM35RVMA CDXM50RVMA CDXM60RVMA CDXM71RVMA Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā 
Indoor airflow rate H Cooling l/s 145 (307) 158 (335) 167 (353) 200 (424) 267 (565) Ā 
Heating (cfm) 145 (307) 158 (335) 167 (353) 200 (424) 267 (565) Ā 
Indoor sound pressure level*1 H/L/SL Cooling dB(A) 35/31/29 37/33/31 38/34/32 Ā 
Heating Ā  35/31/29 37/33/31 38/34/32 Ā 
Indoor sound power level H Cooling dB(A) 49 51 52 Ā 
Heating Ā  49 51 52 Ā 
Fan speed 5 steps, quiet and automatic Ā 
Temperature control Microcomputer control Ā 
Dimensions H x W x D mm 200 x 700 x 620 200 x 900 x 620 200 x 1,100 x 620 Ā 
Machine weight kg 21 25 27 30 Ā 
Piping connections Liquid (flare) mm Ćø6.4 Ā 
Gas (flare) Ćø9.5 Ćø12.7 Ćø15.9 Ā 
Drain VP 20 (Inside diameter Ćø20, Outside diameter Ćø26) Ā 
Heat insulation Both liquid and gas pipes Ā 
External static pressure 30 40 Ā 
Ā 
Note: *1. The values are for the rear-suction inlet of the CDXP-R at an external static pressure of 30 Pa. Values for the bottom-suction inlet can be obtained by adding 6 dB(A). The values are for the rear-suction inlet of the CDXM-R at an external static pressure of 40 Pa. Values for the bottom-suction inlet can be obtained by adding 5 dB(A). When a duct-connected type indoor unit with a reduced external static pressure is installed, values for the bottom-suction inlet are higher.
Duct-Connected Type FMA-R Series
Model name Reverse cycle Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
FMA50RVMA FMA60RVMA FMA71RVMA Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor airflow rate H Cooling l/s 300 383 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating Ā  300Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  383 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor sound pressure level H/L Cooling dB(A) 35/31 38/33 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating Ā  35/31Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  38/33 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor sound power level H Cooling dB(A) 49 52 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating Ā  49Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  52 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Fan speed 3 steps Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Temperature control ā€“ Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Dimensions H x W x D mm 245 x 1,000 x 800 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Machine weight kg 37 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Piping connections Liquid (flare) Ā  Ćø6.4 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Gas (flare) mm Ćø12.7 Ćø15.9 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Drain Ā  VP 25 (Inside diameter Ćø25, Outside diameter Ćø32) Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heat insulation ā€“ Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
External static pressure Rated Pa 50 (50-150*1) Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Note: *1. External static pressure is changeable in 11 stages by remote controller.
Ceiling-Mounted Cassette Type
Model name Reverse cycle Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
FFA25RV1A FFA35RV1A FFA50RV1A FFA60RV1A Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Power supply 1 phase, 220-240 V, 50 Hz Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor airflow rate H Cooling l/s 150 (318) 167 (353) 200 (424) 250 (530) Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating (cfm) 150 (318) 167 (353) 200 (424) 250 (530) Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor sound pressure level H/L Cooling dB(A) 33/27 36/29 38/30 42/34 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating Ā  33/27 36/28 38/28 42/34 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Indoor sound power level H Cooling dB(A) 46 49 51 55 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heating Ā  46 49 51 55 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Fan speed 2 steps Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Temperature control Microcomputer control Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
dimensions H x W x D mm 286 x 575 x 575 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Machine weight kg 17.5 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Piping connections Liquid (flare) Ā  Ćø6.4 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Gas (flare) mm Ćø9.5 Ćø12.7 Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Drain Ā  VP 20 (Inside diameter Ćø20, Outside diameter Ćø26) Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Heat insulation Both liquid and gas pipes Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
Measurement conditions 1. Cooling operation data is based on the following conditions: indoor temp. 27ĖšCDB, 19ĖšCWB; outdoor temp. 35ĖšCDB; piping length 5 m. 2. Heating operation data is based on the following conditions: indoor temp. 20ĖšCDB; outdoor temp. 7ĖšCDB, 6ĖšCWB; piping length 5 m. 3. Sound pressure levels are measured in an anechoic chamber based on temperature conditions 1 and 2 above. These values are normally somewhat higher during actual operation as a result of ambient conditions. Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 
OPTIONS
Ā 
Ā  OUTDOOR UNITĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
No. Item 4MKM68R 4MXM68R 4MKM80R 4MXM80R 5MKM100R 5MXM100R Ā 
1 Air direction adjustment grille KPW5E112 Ā 
2 Drain plug KKP937A4*1 KKP945A4*2 Ā 
3 Demand response enabling device BRP070A46 BRP070A42 Ā 
Notes: *1. One set includes five pieces for five units. *2. One set includes one piece for one unit.
Ā  INDOOR UNIT
No. Item Wall-Mounted Type Ā 
CTXJ25/35/50R CTXM20/25/35/46R CTXM50/60/71R CTXM85/95R Ā 
1 Wired remote controllerĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  *1 BRC073A4 BRC073A4*2 BRC073A4*3 BRC073A4 Ā 
2 Wired remote controller cord (shielded wire) Length of 3 m BRCW901A03 Ā 
Length of 8 m BRCW901A08 Ā 
3 Daikin Mobile Controller BRP072A42 BRP072A42*2 BRP072A42*3 BRP072A42 Ā 
4 Wiring adaptor for time clock / remote controllerĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  *4 (Normal open pulse contact / normal open contact) KRP413AB1S KRP413AB1S*2 KRP413AB1S*3 KRP413AB1S Ā 
5 Titanium apatite deodorising filterĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  *5 KAF970A46 KAF970A48 Ā 
6 Dust collection filter BAFP046A41 BAFP046A41*6 Ā 
7 Wireless remote controller loss prevention with chain KKF910A4 Ā 
8 Remote control PC-board set ā€“ KRP067A41 KRP980B2 ā€“ Ā 
Notes: *1. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally.
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *3. A remote control PC-board set (KRP980B2) is also required for each indoor unit. Notes: *1. A wireless receiver kit (BRC086A2R1) is also required for each indoor unit. *5. The filter is a standard accessory. *6. Two pieces are required for these models. *3. The wiring for the wired remote controller should be obtained locally.
No. Item Duct-Connected Type Ā 
CDXP25/35R CDXM25/35/50R CDXM60/71R FMA50/60/71R Ā 
1 Wireless remote controller Cooling only use BRC086A12 BRC086A22*1 Ā 
Reverse cycle use BRC086A11 BRC086A21*1 Ā 
2 Wireless receiver kit ā€“ BRC086A2R1 Ā 
3 Wired remote controller BRC073A4*2 BRC1E62*3 Ā 
4 Wired remote controller cord (shielded wire) Length of 3 m BRCW901A03 ā€“ Ā 
Length of 8 m BRCW901A08 ā€“ Ā 
5 Wiring adaptor for time clock / remote controllerĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  *4 (Normal open pulse contact / normal open contact) KRP413AB1S ā€“ Ā 
6 Wireless remote controller loss prevention with chain KKF910A4 Ā 
7 Insulation kit for high humidity KDT25N32 KDT25N50 KDT25N63 ā€“ Ā 
8 Remote sensor ā€“ KRCS01-4B Ā 
9 High efficiency filter 65% ā€“ KAFP632B80 Ā 
90% ā€“ KAFP633B80 Ā 
10 Long-life filter ā€“ KAFP631B80 Ā 
11 Filter chamber ā€“ KDDFP63B80 Ā 
12 Service panel White ā€“ KTBJ25K80W Ā 
Fresh white ā€“ KTBJ25K80F Ā 
Brown ā€“ KTBJ25K80T Ā 
13 Air discharge adaptor ā€“ KDAP25A71A Ā 
14 Shield plate for side plate ā€“ KDBD63A160 Ā 
*2. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally.
No. Item Ceiling-Mounted Cassette Type Ā 
1 Decoration panel BYFQ60B3W1 Ā 
2 Wireless remote controller Cooling only use BRC086A22 Ā 
Reverse cycle use BRC086A21 Ā 
3 Wireless receiver kit BRC086A2R2 Ā 
4 Wired remote controllerĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  *2 BRC1E62 Ā 
5 Wireless remote controller loss prevention with chain KKF910A4 Ā 
6 Remote sensor KRCS01-1B Ā 
7 Sealing member of air discharge outlet KDBH44BA60 Ā 
8 Panel spacer KDBQ44BA60A Ā 
9 Replacement long-life filter KAFQ441BA60 Ā 
10 Fresh air intake kit KDDQ44XA60 Ā 
Notes: *1. A wireless receiver kit (BRC086A2R2) is also required for each indoor unit. *2. The wiring for wired remote controller should be obtained locally.
Ā  CONTROL SYSTEMĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
No. Item Wall-Mounted Type Duct-Connected Type Ceiling-Mounted Cassette Type Ā 
CTXJ25/35/50R CTXM20/25/35/46R CTXM50/60/71R CTXM85/95R CDXP-R, CDXM-R FMA-R Ā 
1 Central remote controller DCS302CA61*1 DCS302CA61 DCS302CA61*2 Ā 
2 Unified On/Off controller DCS301BA61*1 DCS301BA61 DCS301BA61*2 Ā 
3 Schedule timer DST301BA61*1 DST301BA61 DST301BA61*2 Ā 
4 Interface adaptor for DIII-NET use KRP928BB2S KRP928BB2S*3 KRP928BB2S*4 KRP928BB2S ā€“ DTA112BA51 Ā 
5 Remote control PC-board set ā€“ KRP067A41 KRP980B2 ā€“ Ā 
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. *2. An interface adaptor for DIII-NET use (DTA112BA51) is also required for each indoor unit. *3. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *4. A remote control PC-board set (KRP980B2) is also required for each indoor unit.

Ā 

Warranty & Downloads
Daikin 5 Years Warranty - Nzdepot
Ā 
Ā 
Ā 
Daikinā€™s 5-year parts and labour warranty applies to split, multi-split and ducted heat pumps purchased and installed in homes across New Zealand 5 Year Warranty

Installation & Warranty Claims Note:

Installation must be undertaken by a professional licensed Aircon technician or/and Electrician.

Additional information

Weight 15 kg
Dimensions 275 Ɨ 1100 Ɨ 299 mm
Save & Share Cart
Your Shopping Cart will be saved and you'll be given a link. You, or anyone with the link, can use it to retrieve your Cart at any time.
Back Save & Share Cart
Your Shopping Cart will be saved with Product pictures and information, and Cart Totals. Then send it to yourself, or a friend, with a link to retrieve it at any time.
Your cart email sent successfully :)

Main Menu