SPECIFICATIONS OUTDOOR UNIT |
Model name |
Reverse cycle |
|
3MXM52RVMA |
4MXM68RVMA |
4MXM80RVMA |
5MXM100RVMA |
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
Max. connected indoor units capacity |
kW |
9.0 |
11.0 |
14.5 |
15.6 |
|
Casing colour |
Ivory white |
|
Compressor type |
Hermetically sealed swing type |
|
Refrigerant type |
R-32 |
|
Outdoor sound pressure level*1 |
Rated/ Quiet |
Cooling |
dB(A) |
45/43 |
47/44 |
48/45 |
48/46 |
|
Heating |
|
47/45 |
48/46 |
49/47 |
|
Outdoor sound power level |
H |
Cooling |
dB(A) |
57 |
59 |
60 |
|
Heating |
|
59 |
60 |
61 |
|
Dimensions |
H x W x D |
mm |
695 x 930 x 350 |
990 x 940 x 320 |
|
Machine weight |
kg |
53 |
56 |
61 |
83 |
|
Outdoor operating range |
Cooling |
˚CDB |
-10 to 46 |
|
Heating |
˚CWB |
-15 to 18 |
|
|
Max. piping length |
m |
50 (total) |
60 (total) |
70 (total) |
80 (total) |
|
30 (for one room) |
|
|
Additional charge |
g/m |
20 (for over 40 m) |
|
Max. level difference |
m |
15 (between indoor and outdoor units) / 7.5 (between indoor units) |
|
|
Note: *1. The value to the left of the slash is for rated operation. The value to the right is when using Outdoor Unit Quiet Operation. |
INDOOR UNIT |
Wall-Mounted Type CTXJ-R Series |
Model name |
Reverse cycle |
|
CTXJ25RVMAW |
CTXJ25RVMAS |
CTXJ35RVMAW |
CTXJ35RVMAS |
CTXJ50RVMAW |
CTXJ50RVMAS |
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
Front panel colour |
White |
Silver |
White |
Silver |
White |
Silver |
|
Indoor airflow rate |
H |
Cooling |
l/s |
138 (293) |
177 (374) |
180 (381) |
|
Heating |
(cfm) |
173 (367) |
198 (420) |
207 (438) |
|
Indoor sound pressure level |
H/L/SL |
Cooling |
dB(A) |
38/25/21 |
45/26/22 |
46/35/32 |
|
Heating |
|
41/28/21 |
45/29/22 |
47/35/32 |
|
Indoor sound power level |
H |
Cooling |
dB(A) |
52 |
59 |
60 |
|
Heating |
|
55 |
59 |
61 |
|
Fan speed |
5 steps, quiet and automatic |
|
Temperature control |
Microcomputer control |
|
Dimensions |
H x W x D |
mm |
303 × 998 × 212 |
|
Machine weight |
kg |
12 |
|
Piping connections |
Liquid (flare) |
mm |
ø6.4 |
|
Gas (flare) |
ø9.5 |
ø12.7 |
|
Drain |
ø16.0 |
|
Heat insulation |
Both liquid and gas pipes |
|
Wall-Mounted Type CTXM-R Series |
Model name |
Reverse cycle |
|
CTXM20RVMA |
CTXM25RVMA |
CTXM35RVMA |
CTXM46RVMA |
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
Front panel colour |
White |
|
Indoor airflow rate |
H |
Cooling |
l/s |
155 (328) |
173 (367) |
188 (399) |
203 (431) |
|
Heating |
(cfm) |
160 (339) |
173 (367) |
188 (399) |
202 (427) |
|
Indoor sound pressure level |
H/L/SL |
Cooling |
dB(A) |
38/25/19 |
40/25/19 |
42/26/19 |
44/35/26 |
|
Heating |
|
39/28/20 |
40/28/20 |
42/29/20 |
43/33/26 |
|
Indoor sound power level |
H |
Cooling |
dB(A) |
52 |
54 |
56 |
58 |
|
Heating |
|
53 |
54 |
56 |
57 |
|
Fan speed |
5 steps, quiet and automatic |
|
Temperature control |
Microcomputer control |
|
Dimensions |
H x W x D |
mm |
285 x 770 x 223 |
|
Machine weight |
kg |
9 |
|
Piping connections |
Liquid (flare) |
mm |
ø6.4 |
|
Gas (flare) |
ø9.5 |
ø12.7 |
|
Drain |
ø16.0 |
|
Heat insulation |
Both liquid and gas pipes |
|
Model name |
Reverse cycle |
|
CTXM50RVMA |
CTXM60RVMA |
CTXM71RVMA |
CTXM85RVMA |
CTXM95RVMA |
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
Front panel colour |
White |
|
Indoor airflow rate |
H |
Cooling |
l/s |
282 (597) |
325 (689) |
333 (706) |
398 (844) |
400 (848) |
|
Heating |
(cfm) |
287 (607) |
333 (706) |
328 (696) |
422 (893) |
413 (876) |
|
Indoor sound pressure level |
H/L/SL |
Cooling |
dB(A) |
45/35/28 |
48/36/29 |
49/37/30 |
51/40/37 |
53/42/38 |
|
Heating |
|
45/33/28 |
48/33/29 |
49/35/30 |
51/38/35 |
52/38/35 |
|
Indoor sound power level |
H |
Cooling |
dB(A) |
59 |
62 |
63 |
65 |
67 |
|
Heating |
|
59 |
62 |
63 |
65 |
66 |
|
Fan speed |
5 steps, quiet and automatic |
|
Temperature control |
Microcomputer control |
|
Dimensions |
H x W x D |
mm |
295 x 990 x 263 |
340 x 1,200 x 259 |
|
Machine weight |
kg |
13 |
17 |
18 |
|
Piping connections |
Liquid (flare) |
mm |
ø6.4 |
|
Gas (flare) |
ø12.7 |
ø15.9 |
|
Drain |
ø16.0 |
|
Heat insulation |
Both liquid and gas pipes |
|
SPECIFICATIONS (CONT) Duct-Connected Type CDXP-R and CDXM-R Series |
Model name |
Reverse cycle |
|
CDXP25RVMA |
CDXP35RVMA |
CDXM25RVMA |
CDXM35RVMA |
CDXM50RVMA |
CDXM60RVMA |
CDXM71RVMA |
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
Indoor airflow rate |
H |
Cooling |
l/s |
145 (307) |
158 (335) |
167 (353) |
200 (424) |
267 (565) |
|
Heating |
(cfm) |
145 (307) |
158 (335) |
167 (353) |
200 (424) |
267 (565) |
|
Indoor sound pressure level*1 |
H/L/SL |
Cooling |
dB(A) |
35/31/29 |
37/33/31 |
38/34/32 |
|
Heating |
|
35/31/29 |
37/33/31 |
38/34/32 |
|
Indoor sound power level |
H |
Cooling |
dB(A) |
49 |
51 |
52 |
|
Heating |
|
49 |
51 |
52 |
|
Fan speed |
5 steps, quiet and automatic |
|
Temperature control |
Microcomputer control |
|
Dimensions |
H x W x D |
mm |
200 x 700 x 620 |
200 x 900 x 620 |
200 x 1,100 x 620 |
|
Machine weight |
kg |
21 |
25 |
27 |
30 |
|
Piping connections |
Liquid (flare) |
mm |
ø6.4 |
|
Gas (flare) |
ø9.5 |
ø12.7 |
ø15.9 |
|
Drain |
VP 20 (Inside diameter ø20, Outside diameter ø26) |
|
Heat insulation |
Both liquid and gas pipes |
|
External static pressure |
30 |
40 |
|
|
Note: *1. The values are for the rear-suction inlet of the CDXP-R at an external static pressure of 30 Pa. Values for the bottom-suction inlet can be obtained by adding 6 dB(A). The values are for the rear-suction inlet of the CDXM-R at an external static pressure of 40 Pa. Values for the bottom-suction inlet can be obtained by adding 5 dB(A). When a duct-connected type indoor unit with a reduced external static pressure is installed, values for the bottom-suction inlet are higher. |
Duct-Connected Type FMA-R Series |
Model name |
Reverse cycle |
|
|
|
|
|
|
|
|
|
|
|
|
|
FMA50RVMA |
FMA60RVMA |
FMA71RVMA |
|
|
|
|
|
|
|
|
|
|
|
|
|
Power supply |
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor airflow rate |
H |
Cooling |
l/s |
300 |
383 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
|
300 383 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor sound pressure level |
H/L |
Cooling |
dB(A) |
35/31 |
38/33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
|
35/31 38/33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor sound power level |
H |
Cooling |
dB(A) |
49 |
52 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
|
49 52 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan speed |
3 steps |
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperature control |
– |
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions |
H x W x D |
mm |
245 x 1,000 x 800 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Machine weight |
kg |
37 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Piping connections |
Liquid (flare) |
|
ø6.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Gas (flare) |
mm |
ø12.7 |
ø15.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Drain |
|
VP 25 (Inside diameter ø25, Outside diameter ø32) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat insulation |
– |
|
|
|
|
|
|
|
|
|
|
|
|
|
External static pressure |
Rated |
Pa |
50 (50-150*1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: *1. External static pressure is changeable in 11 stages by remote controller. |
Ceiling-Mounted Cassette Type |
Model name |
Reverse cycle |
|
|
|
|
|
|
|
|
|
|
|
|
|
FFA25RV1A |
FFA35RV1A |
FFA50RV1A |
FFA60RV1A |
|
|
|
|
|
|
|
|
|
|
|
|
|
Power supply |
1 phase, 220-240 V, 50 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor airflow rate |
H |
Cooling |
l/s |
150 (318) |
167 (353) |
200 (424) |
250 (530) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
(cfm) |
150 (318) |
167 (353) |
200 (424) |
250 (530) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor sound pressure level |
H/L |
Cooling |
dB(A) |
33/27 |
36/29 |
38/30 |
42/34 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
|
33/27 |
36/28 |
38/28 |
42/34 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor sound power level |
H |
Cooling |
dB(A) |
46 |
49 |
51 |
55 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heating |
|
46 |
49 |
51 |
55 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan speed |
2 steps |
|
|
|
|
|
|
|
|
|
|
|
|
|
Temperature control |
Microcomputer control |
|
|
|
|
|
|
|
|
|
|
|
|
|
dimensions |
H x W x D |
mm |
286 x 575 x 575 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Machine weight |
kg |
17.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Piping connections |
Liquid (flare) |
|
ø6.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Gas (flare) |
mm |
ø9.5 |
ø12.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Drain |
|
VP 20 (Inside diameter ø20, Outside diameter ø26) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Heat insulation |
Both liquid and gas pipes |
|
|
|
|
|
|
|
|
|
|
|
|
|
Measurement conditions 1. Cooling operation data is based on the following conditions: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5 m. 2. Heating operation data is based on the following conditions: indoor temp. 20˚CDB; outdoor temp. 7˚CDB, 6˚CWB; piping length 5 m. 3. Sound pressure levels are measured in an anechoic chamber based on temperature conditions 1 and 2 above. These values are normally somewhat higher during actual operation as a result of ambient conditions. |
|
|
|
|
|
|
|
|
|
|
|
|
OUTDOOR UNIT |
No. |
Item |
4MKM68R |
4MXM68R |
4MKM80R |
4MXM80R |
5MKM100R |
5MXM100R |
|
1 |
Air direction adjustment grille |
KPW5E112 |
|
2 |
Drain plug |
KKP937A4*1 |
KKP945A4*2 |
|
3 |
Demand response enabling device |
BRP070A46 |
BRP070A42 |
|
Notes: *1. One set includes five pieces for five units. *2. One set includes one piece for one unit. |
INDOOR UNIT |
No. |
Item |
Wall-Mounted Type |
|
CTXJ25/35/50R |
CTXM20/25/35/46R |
CTXM50/60/71R |
CTXM85/95R |
|
1 |
Wired remote controller *1 |
BRC073A4 |
BRC073A4*2 |
BRC073A4*3 |
BRC073A4 |
|
2 |
Wired remote controller cord (shielded wire) |
Length of 3 m |
BRCW901A03 |
|
Length of 8 m |
BRCW901A08 |
|
3 |
Daikin Mobile Controller |
BRP072A42 |
BRP072A42*2 |
BRP072A42*3 |
BRP072A42 |
|
4 |
Wiring adaptor for time clock / remote controller *4 (Normal open pulse contact / normal open contact) |
KRP413AB1S |
KRP413AB1S*2 |
KRP413AB1S*3 |
KRP413AB1S |
|
5 |
Titanium apatite deodorising filter *5 |
KAF970A46 |
KAF970A48 |
|
6 |
Dust collection filter |
BAFP046A41 |
BAFP046A41*6 |
|
7 |
Wireless remote controller loss prevention with chain |
KKF910A4 |
|
8 |
Remote control PC-board set |
– |
KRP067A41 |
KRP980B2 |
– |
|
Notes: *1. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally. |
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *3. A remote control PC-board set (KRP980B2) is also required for each indoor unit. Notes: *1. A wireless receiver kit (BRC086A2R1) is also required for each indoor unit. |
*5. The filter is a standard accessory. *6. Two pieces are required for these models. *3. The wiring for the wired remote controller should be obtained locally. |
No. |
Item |
Duct-Connected Type |
|
CDXP25/35R |
CDXM25/35/50R |
CDXM60/71R |
FMA50/60/71R |
|
1 |
Wireless remote controller |
Cooling only use |
BRC086A12 |
BRC086A22*1 |
|
Reverse cycle use |
BRC086A11 |
BRC086A21*1 |
|
2 |
Wireless receiver kit |
– |
BRC086A2R1 |
|
3 |
Wired remote controller |
BRC073A4*2 |
BRC1E62*3 |
|
4 |
Wired remote controller cord (shielded wire) |
Length of 3 m |
BRCW901A03 |
– |
|
Length of 8 m |
BRCW901A08 |
– |
|
5 |
Wiring adaptor for time clock / remote controller *4 (Normal open pulse contact / normal open contact) |
KRP413AB1S |
– |
|
6 |
Wireless remote controller loss prevention with chain |
KKF910A4 |
|
7 |
Insulation kit for high humidity |
KDT25N32 |
KDT25N50 |
KDT25N63 |
– |
|
8 |
Remote sensor |
– |
KRCS01-4B |
|
9 |
High efficiency filter |
65% |
– |
KAFP632B80 |
|
90% |
– |
KAFP633B80 |
|
10 |
Long-life filter |
– |
KAFP631B80 |
|
11 |
Filter chamber |
– |
KDDFP63B80 |
|
12 |
Service panel |
White |
– |
KTBJ25K80W |
|
Fresh white |
– |
KTBJ25K80F |
|
Brown |
– |
KTBJ25K80T |
|
13 |
Air discharge adaptor |
– |
KDAP25A71A |
|
14 |
Shield plate for side plate |
– |
KDBD63A160 |
|
*2. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required.*4. The time clock and other devices should be obtained locally. |
No. |
Item |
Ceiling-Mounted Cassette Type |
|
1 |
Decoration panel |
BYFQ60B3W1 |
|
2 |
Wireless remote controller |
Cooling only use |
BRC086A22 |
|
Reverse cycle use |
BRC086A21 |
|
3 |
Wireless receiver kit |
BRC086A2R2 |
|
4 |
Wired remote controller *2 |
BRC1E62 |
|
5 |
Wireless remote controller loss prevention with chain |
KKF910A4 |
|
6 |
Remote sensor |
KRCS01-1B |
|
7 |
Sealing member of air discharge outlet |
KDBH44BA60 |
|
8 |
Panel spacer |
KDBQ44BA60A |
|
9 |
Replacement long-life filter |
KAFQ441BA60 |
|
10 |
Fresh air intake kit |
KDDQ44XA60 |
|
Notes: *1. A wireless receiver kit (BRC086A2R2) is also required for each indoor unit. *2. The wiring for wired remote controller should be obtained locally. |
CONTROL SYSTEM |
No. |
Item |
Wall-Mounted Type |
Duct-Connected Type |
Ceiling-Mounted Cassette Type |
|
CTXJ25/35/50R |
CTXM20/25/35/46R |
CTXM50/60/71R |
CTXM85/95R |
CDXP-R, CDXM-R |
FMA-R |
|
1 |
Central remote controller |
DCS302CA61*1 |
DCS302CA61 |
DCS302CA61*2 |
|
2 |
Unified On/Off controller |
DCS301BA61*1 |
DCS301BA61 |
DCS301BA61*2 |
|
3 |
Schedule timer |
DST301BA61*1 |
DST301BA61 |
DST301BA61*2 |
|
4 |
Interface adaptor for DIII-NET use |
KRP928BB2S |
KRP928BB2S*3 |
KRP928BB2S*4 |
KRP928BB2S |
– |
DTA112BA51 |
|
5 |
Remote control PC-board set |
– |
KRP067A41 |
KRP980B2 |
– |
|
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. *2. An interface adaptor for DIII-NET use (DTA112BA51) is also required for each indoor unit. |