Cooling Capacity: 5.00 kW
Heating Capacity: 6.00 kW
Please fill in the fields below with the shipping destination details in order to calculate the shipping cost.
Power Up Your Space with Panasonic 5.0kW AC🤩
Looking for a powerful and efficient air conditioner Check out Panasonic s 5 0kW Developer AC With advanced features and sleek design
Power Up Your Space with Panasonic 5.0kW AC – Stay Cool, Breathe Easy, and Save Energy | Buy Now
Experience unmatched comfort with Panasonic’s 5.0kW AC. Stay cool, breathe easy, and save energy with this powerful, energy-efficient air conditioning unit. Buy now and power up your living space!
Enjoy Comfortable Living with Panasonic 5.0kW AC
Description 1: Stay cool and comfortable all year round with Panasonic’s 5.0kW AC. Equipped with advanced features and cutting-edge technology, this powerful air conditioning unit ensures that you always feel relaxed and refreshed, even on the hottest days. With its high cooling capacity and energy-efficient operation, the Panasonic 5.0kW AC is perfect for large living spaces, such as living rooms and bedrooms.
Stay Healthy with Panasonic 5.0kW AC
Description 2: Breathe easy and enjoy a healthy living environment with Panasonic’s 5.0kW AC. This air conditioning unit comes equipped with advanced air filtration systems that remove dust, allergens, and other harmful particles from the air. With its high-quality air purification technology, the Panasonic 5.0kW AC ensures that you and your family are always breathing clean, fresh air.
Save Money and Energy with Panasonic 5.0kW AC
Description 3: Cut down on your energy bills and reduce your carbon footprint with Panasonic’s 5.0kW AC. This energy-efficient air conditioning unit is designed to consume less power while delivering exceptional cooling performance. Equipped with advanced sensors and intelligent control systems, the Panasonic 5.0kW AC adjusts its cooling capacity to match your cooling needs, thereby saving energy and reducing your electricity bills.
- “Panasonic 5.0kW AC: Stay Cool and Comfortable”
- “Breathe Easy with Panasonic 5.0kW AC”
- “Save Money and Energy with Panasonic 5.0kW AC”
- “Upgrade Your Home with Panasonic 5.0kW AC”
- “Experience Unmatched Comfort with Panasonic 5.0kW AC”
- Panasonic 5.0kW AC
- air conditioning unit
- cooling capacity
- energy-efficient operation
- advanced air filtration systems
- clean, fresh air
- reduce energy bills
- intelligent control systems
- comfortable living
- healthy living environment
Panasonic 5.0kW Developer Series Standard Reverse Cycle INVERTER Air Conditioner
- Cooling Capacity: 5.00 kW
- Heating Capacity: 6.00 kW
Panasonic’s INVERTER reduces power consumption by varying the speed of the compressor according to the temperature changes with the aim of minimising temperature fluctuations so you can enjoy consistent cooling comfort.
SMARTIFY YOUR AIR • Smart Control • 24hr Air Purification • Analyse Usage Patterns • Effortless, Intuitive Troubleshooting
MODELÂ Â Â Â Â Â Â Â Â INDOOR UNIT (240V / 1 Phase / 50Hz) OUTDOOR UNIT | CS-RZ25XKRW CU-RZ25XKR | CS-RZ35XKRW CU-RZ35XKR | CS-RZ42XKRW CU-RZ42XKR | CS-RZ50XKRW CU-RZ50XKR | CS-RZ60XKRW CU-RZ60XKR | CS-RZ71XKRW CU-RZ71XKR | CS-RZ80XKR CU-RZ80XKR | |||||||||||
Cooling / Heating Capacity | (min-max)Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â kW | 2.50 (0.95-3.70) 3.00 (0.90-4.40) | 3.50 (1.00-4.20) 4.00 (0.90-5.70) | 4.20 (1.15-5.10) 5.10 (0.90-6.80) | 5.00 (1.15-6.10) 6.00 (0.98-7.70) | 6.00 (1.25-6.90) 6.50 (0.98-8.20) | 7.10 (1.70-8.50) 8.00 (1.70-10.60) | 8.00 (2.30-9.00) 9.00 (2.20-11.60) | ||||||||||
(min-max)Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Btu/h | 8,530 (3,240-12,600) 10,200 (3,070-15,000) | 11,900 (3,410-14,300) 13,600 (3,070-19,400) | 14,300 (3,920-17,400) 17,400 (3,070-23,200) | 17,100 (3,920-20,800) 20,500 (3,340-26,300) | 20,500 (4,260-23,500) 22,200 (3,340-28,000) | 24,200 (5,800-29,000) 27,300 (5,800-36,100) | 27,300 (7,840-30,700) 30,700 (7,500-39,600) | |||||||||||
Air Flow                  Indoor                              L/s | 188/200 | 193/202 | 193/202 | 208/228 | 328/339 | 352/367 | 367/377 | |||||||||||
Dehumid                                                         L/h | 1.5 | 2.0 | 2.4 | 2.8 | 3.3 | 4.1 | 4.7 | |||||||||||
Electrical Data | Running Current                  A | 2.50/2.80 | 3.50/3.80 | 5.00/5.70 | 6.50/7.30 | 7.90/8.00 | 8.80/8.90 | 11.30/11.40 | ||||||||||
Max Current                        A | 6.4 | 7.2 | 8.9 | 11.0 | 11.6 | 14.8 | 15.8 | |||||||||||
Power Input (min-max)Â Â Â Â Â Â Â kW | 0.57 (0.22-1.20) 0.64 (0.19-1.29) | 0.80 (0.22-1.29) 0.86 (0.19-1.65) | 1.18 (0.24-1.64) 1.36 (0.20-2.04) | 1.51 (0.24-2.10) 1.72 (0.26-2.50) | 1.85 (0.35-2.20) 1.89 (0.26-2.64) | 2.06 (0.45-2.90) 2.09 (0.40-3.30) | 2.44 (0.46-3.10) 2.46 (0.44-3.60) | |||||||||||
AEER / EERÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â W/W ACOP / COPÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â W/W | 4.32/4.39 4.63/4.69 | 4.33/4.38 4.61/4.65 | 3.53/3.56 3.73/3.75 | 3.29/3.31 3.47/3.49 | 3.23/3.24 3.42/3.44 | 3.43/3.45 3.81/3.83 | 3.26/3.28 3.64/3.66 | |||||||||||
Star Rating Residential/ Commercial | Hot Climate                  TCSPF HSPF | 4.5/6.0 3.5/3.5 | 4.5/5.5 3.5/3.5 | 3.5/4.5 3.0/3.0 | 3.5/4.5 3.0/3.0 | 3.5/4.5 3.5/3.5 | 3.5/4.5 3.5/3.5 | 3.5/4.0 3.5/3.5 | ||||||||||
Average Climate           TCSPF HSPF | 4.0/6.5 3.0/3.0 | 4.0/6.5 3.0/3.5 | 3.5/5.0 2.5/2.5 | 3.5/6.0 2.5/2.5 | 3.5/5.5 3.0/3.0 | 3.5/5.0 2.5/3.0 | 3.5/5.0 2.5/3.0 | |||||||||||
Cold Climate                TCSPF HSPF | 4.0/8.0 2.5/2.5 | 4.5/7.5 2.5/3.0 | 3.5/6.0 2.0/2.0 | 3.5/8.0 2.0/2.0 | 3.5/7.0 2.0/2.5 | 3.5/6.0 2.0/2.5 | 3.5/6.0 2.0/2.5 | |||||||||||
Noise Level | Sound Pressure Level*2Â dB(A) | Indoor (H / L / Q-Lo) | 40/25/19 40/27/21 | 44/26/19 44/29/22 | 44/31/28 44/32/28 | 44/34/28 44/33/29 | 47/36/33 48/36/33 | 49/37/34 49/37/34 | 51/38/35 50/38/35 | |||||||||
Outdoor (H / Q-Lo) | 48/43 49/44 | 49/44 50/45 | 49/44 51/46 | 48/43 49/44 | 49/44 51/46 | 54/49 54/49 | 55/50 55/50 | |||||||||||
Sound Power Level dB(A) | Indoor (H / L / Q-Lo) | 56/41/35 56/43/37 | 60/42/35 60/45/38 | 60/47/44 60/48/44 | 60/50/44 60/49/45 | 63/52/49 64/52/49 | 65/53/50 65/53/50 | 67/54/51 66/54/51 | ||||||||||
Outdoor (H / Q-Lo) | 63/58 64/59 | 64/59 65/60 | 64/59 66/61 | 63/58 64/59 | 64/59 66/61 | 68/63 68/63 | 69/64 69/64 | |||||||||||
Net Weight              Indoor (Outdoor)                 kg | 8 (25) | 8 (30) | 8 (31) | 8 (35) | 12 (35) | 13 (45) | 16 (60) | |||||||||||
Dimensions             Indoor  (H x W x D)            mm Outdoor (H x W x D)            mm | 290 x 779 x 209 542 x 780 x 289 | 290 x 779 x 209 542 x 780 x 289 | 290 x 779 x 209 619 x 824 x 299 | 290 x 779 x 209 619 x 824 x 299 | 295 x 1,040 x 244 619 x 824 x 299 | 295 x 1,040 x 244 695 x 875 x 320 | 295 x 1,040 x 244 795 x 875 x320 | |||||||||||
Refrigerator Pipe Diameter | Liquid Side              mm/(inch) | ø 6.35 (1/4) | ø 6.35 (1/4) | ø 6.35 (1/4) | ø 6.35 (1/4) | ø 6.35 (1/4) | ø 6.35 (1/4) | ø 6.35 (1/4) | ||||||||||
Gas Side                 mm/(inch) | ø 9.52 (3/8) | ø 9.52 (3/8) | ø 12.70 (1/2) | ø 12.70 (1/2) | ø 12.70 (1/2) | ø 15.88 (5/8) | ø 15.88 (5/8) | |||||||||||
Pipe Extension Length                       Min ~ Max (m) | 3~20 | 3~20 | 3~20 | 3~30 | 3~30 | 3~30 | 3~30 | |||||||||||
Maximum Elevation Length                                 m | 15 | 15 | 15 | 15 | 15 | 20 | 20 | |||||||||||
Pipe Length For Additional Gas                            m | 7.5 | 7.5 | 7.5 | 10.0 | 10.0 | 10.0 | 10.0 | |||||||||||
Additional Gas Amount                                    g/m | 10 | 10 | 10 | 15 | 15 | 25 | 25 | |||||||||||
Power Supply | Outdoor | Outdoor | Outdoor | Outdoor | Outdoor | Outdoor | Outdoor | |||||||||||
Operating Range (Outdoor)      Cooling    Degree °C Heating | -10 ~ +46 -15 ~ +24 | -10 ~ +46 -15 ~ +24 | -10 ~ +46 -15 ~ +24 | +10 ~ +46 -15 ~ +24 | -10 ~ +46 -15 ~ +24 | -10 ~ +46 -15 ~ +24 | -10 ~ +46 -15 ~ +24 | |||||||||||
Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
*1 Indoor temperature display and some special function are not available through the App for all models. | Cooling (    ): Outdoor Unit EER: Cooling Efficiency | ||||||||||||||||||
*2 Sound pressure level specification is measured according to JIS C9612. | Heating | COP: Heating Efficiency |